What is a shell-and-tube condenser?

1. The shell-and-tube condenser is a commonly used heat exchanger in chillers. Similar to the shell-and-tube evaporator, it consists of a shell, tube sheets, a bundle of heat-transfer tubes, a cooling-water distribution component (such as a water cap or header), and inlet and outlet connections for both the cooling water and the refrigerant, forming a closed water-cooled condenser. 2. For small condensers, the shell can be fabricated from thick seamless steel tubing. Larger condensers, however, are typically constructed by rolling and welding steel plates into a cylindrical shell. Tube sheets are welded to both ends of the shell, creating a complete pressure vessel. Numerous holes (tube holes) are machined into the tube sheets; after the heat-transfer tube bundle is inserted through these holes, its ends are joined to the tube sheets either by expansion joints or welding, and must possess…


09-22

2014

What is an oil separator?

An oil separator is designed to remove lubricating oil from the high-pressure vapor discharged by the refrigeration compressor, ensuring the system operates safely and efficiently. Based on the principle of oil separation—reducing airflow velocity and changing its direction—the oil droplets in the high-pressure vapor are separated under the influence of gravity. Typically, when the airflow velocity is below 1 m/s, oil particles with diameters greater than 0.2 mm can be effectively removed from the vapor. Common types of oil separators include scrubber-type, centrifugal-type, packed-bed type, and filter-type. 1. Structure The oil separator is installed between the compressor outlet and the condenser inlet. Through this separation process, the performance of both the condenser and the evaporator is improved.


09-23

2014

Principle of the Variable-Flow Heat Exchanger

Currently, in the cold northern regions of China, traditional centralized heating relies predominantly on coal combustion. The resulting emissions of smoke and particulate matter frequently give rise to severe smog and dangerously high PM2.5 levels during winter in northern cities. Consequently, in recent years, the government has vigorously promoted clean heating solutions. Many buildings have replaced conventional coal-fired boilers with water-source heat pump units as their primary heating systems, with water-to-water heat pumps being the predominant choice. On the market, most water-to-water heat pump units employ a water‑path switching mechanism to switch between cooling and heating modes: in summer, when cooling is required, the source water—such as groundwater, river water, or lake water—flows into the unit’s condenser and interacts with…


09-23

2014

High-efficiency oil–gas separator for parallel screw compressor units

Currently, large-scale low-temperature freezing and refrigeration facilities commonly employ multi‑unit parallel screw refrigeration systems. However, screw compressors typically operate with oil‑injection compression, which causes a portion of the refrigeration oil to be carried out of the compressor in the discharge stream. To prevent this oil from entering the system—where it could compromise both the reliable operation of the compressor and the heat‑transfer efficiency of the condenser—it is necessary to install an oil–gas separator at the compressor’s discharge end. ColdDe has developed a product series specifically for screw compressors without built‑in oil separators, particularly for parallel screw compressor‑condenser units. Thanks to its unique performance characteristics and structural design, this series ensures an adequate supply of lubricating oil.


09-23

2014

Low-pressure circulation tank for fluorine

The low-pressure accumulator, formally known as the low-pressure liquid receiver, is primarily used in forced‑liquid supply systems. It circulates low‑pressure refrigerant via a pump while simultaneously performing gas–liquid separation. Its main components include the cylindrical body, end caps, a suction‑gas connection (to the evaporator’s suction port), a discharge‑gas connection (to the compressor’s suction port), a liquid outlet (connected to the refrigeration pump inlet), an oil drain port, a liquid‑supply port (connected to the high‑pressure liquid line), a bypass connection, a safety‑valve connection, liquid‑level control ports (one each at the top and bottom), and a gas‑bypass connection (to the refrigeration pump’s gas discharge outlet). Low‑pressure accumulators of varying capacities are selected according to the required cooling capacity, with volumes ranging from 1 to 10 cubic meters. Historically, low‑pressure accumulators have been widely used…


09-23

2014

Development of Tube Bundle Support Structures for Shell-and-Tube Heat Exchangers

The evolution of shell‑side baffles and tube bundle supports in shell-and-tube heat exchangers is reflected in the modification and advancement of baffle designs. These innovations aim to eliminate thermal dead zones in the shell-side fluid flow by developing and refining support structures for the shell-side heat transfer tubes, thereby enhancing shell-side heat transfer performance, reducing shell-side flow resistance, increasing flow velocity, and minimizing fouling—ultimately achieving intensified heat transfer, reduced corrosion, and improved vibration resistance of the tube bundle. Current configurations can be categorized into baffle plates, baffle rods, and other structural types. The incorporation of baffle plates increases the shell-side fluid velocity, enhances turbulence, and ensures that the shell-side fluid flows perpendicularly across the tube bundle, thus improving…