Development of Tube Bundle Support Structures for Shell-and-Tube Heat Exchangers
The evolution of shell‑side baffles and tube bundle supports in shell-and-tube heat exchangers is reflected in the modification and advancement of baffle designs. These innovations aim to eliminate thermal dead zones in the shell-side fluid flow by developing and refining support structures for the shell-side heat transfer tubes, thereby enhancing shell-side heat transfer performance, reducing shell-side flow resistance, increasing flow velocity, and minimizing fouling—ultimately achieving intensified heat transfer, reduced corrosion, and improved vibration resistance of the tube bundle. Current configurations can be categorized into baffle plates, baffle rods, and other structural types. The incorporation of baffle plates increases the shell-side fluid velocity, enhances turbulence, and ensures that the shell-side fluid flows perpendicularly across the tube bundle, thus improving…
09-23
2014
Shell-and-tube continuous helical baffle heat exchanger
The so‑called continuous helical baffle heat exchanger eliminates the arc‑shaped baffles traditionally used in shell‑and‑tube heat exchangers to control fluid flow direction and velocity, replacing them with continuous helical baffles—more accurately termed helical flow guides. Within the shell, these continuous helical flow guides direct the fluid along a continuous, closed spiral path whose cross‑sectional area remains constant; in other words, throughout its entire passage through the shell side, the fluid follows a stable helical trajectory. This fundamentally transforms the zigzag, back-and-forth flow pattern characteristic of conventional shell‑and‑tube heat exchangers with arc‑shaped baffles, marking a revolutionary change in the flow dynamics on the shell side. And now…
09-24
2014
Introduction to the Lengde Seawater Heat Exchanger
During the 12th Five-Year Plan period, China will enter a critical phase of strengthening its capacity to safeguard maritime rights and interests, transforming its marine economic growth model, adjusting its industrial structure, and establishing an emerging strategic marine industry system. Faced with increasingly severe challenges in maritime rights protection and marine ecological conservation, as well as the substantial demand for the development and utilization of marine resources, the marine equipment manufacturing sector is poised for rapid growth, driving robust demand for seawater heat exchange equipment. However, seawater contains high concentrations of dissolved oxygen, chloride ions, and microorganisms, which pose significant corrosive risks to metal heat exchangers. Therefore, seawater heat exchangers must address corrosion‑resistance issues. Lengde Company is dedicated to developing corrosion‑resistant heat exchangers.
09-24
2014
Discussion on Anti-Corrosion Technologies for Seawater Heat Exchangers
Corrosion is a pervasive issue across all sectors and industries, posing significant threats to national economic development, human well-being, and the environment. Corrosion frequently leads to shortened plant operating cycles, premature failure of equipment and facilities, reduced service life, and environmental pollution; it also hinders the smooth advancement of new technologies. According to statistics, annual economic losses attributable to corrosion in various countries typically account for 1% to 5% of their respective gross domestic product, varying with each country’s level of economic development and its capacity for corrosion control. In China, the losses caused by corrosion are particularly severe; according to data from the “China Corrosion Survey Report,” the country’s annual corrosion-related losses in recent years have amounted to approximately…
09-24
2014
Introduction to High-Efficiency Oil-Gas Separators
Currently, large central air-conditioning systems and low-temperature refrigeration facilities commonly employ screw-type chillers. However, screw compressors typically operate with oil‑injection, and the compressor discharge carries a portion of the refrigeration oil out of the unit. To prevent this oil from entering the system—particularly in chiller and low‑temperature freezer units that use flooded evaporators, where oil return is especially challenging—and to avoid significant adverse effects on heat‑exchanger efficiency, it is necessary to install an oil–gas separator at the compressor discharge. Although existing technologies incorporate built‑in oil–gas separators within the compressor, their separation performance remains inadequate, leaving substantial amounts of oil still present.
09-25
2014
Freeze Damage and Anti-Freeze Measures for Shell-and-Tube Heat Exchangers
Shell-and-tube heat exchangers used in refrigeration systems frequently experience failures that paralyze the refrigeration circuit and result in substantial economic losses due to tube ruptures. One of the most common causes of such tube failures is ice formation on the water side of the heat exchanger: as the ice expands, it can either burst or crush the tubes. Condensers and flooded evaporators are typically prone to tube damage caused by ice‑induced expansion, whereas dry‑type evaporators more often suffer from tube damage due to ice‑induced compression. The primary reasons for water freezing inside the heat exchanger fall into the following categories: 1. When the unit remains shut down for an extended period and the water has not been drained or has not been completely removed, any residual water within the tubes will freeze and expand upon ambient temperatures dropping below 0°C, ultimately causing the tubes to rupture. For…
09-25
2014
Design of a Water-Cooled Screw Chiller System for Air Conditioning
Common water-cooled screw chillers are primarily classified into three types based on evaporator design: dry‑type units, flooded‑type units, and falling‑film units. The core component of a water‑cooled screw chiller is the screw compressor; the market is dominated by twin‑screw compressors, with a few manufacturers opting for single‑screw models. Most compressors are semi‑hermetic, though some manufacturers also offer open‑type or fully hermetic designs. With the exception of major U.S. and Japanese brands, domestic manufacturers generally source their compressors from external suppliers. The system designs of dry‑type water‑cooled screw chillers across different manufacturers are largely similar, differing mainly in heat exchanger and throttling‑device configurations. On the market, leading manufacturers employ broadly comparable condenser designs (condensing…
09-27
2014
Currently, screw-type water-cooled chillers are widely used in the large‑scale central air-conditioning market. As energy‑efficiency requirements continue to rise, these units are increasingly equipped with flooded evaporators—heat exchangers that offer a higher heat transfer coefficient. Because flooded evaporators rely on boiling heat transfer outside the tubes, they deliver superior thermal performance, enabling higher evaporation temperatures and smaller temperature differences across the heat exchanger, thereby improving the chiller’s energy efficiency ratio. However, flooded‑type systems also present certain technical challenges, resulting in higher failure rates and greater costs compared with dry‑type units. Moreover, oil return in flooded systems is more difficult than in dry‑type systems, and their control strategies are more complex, which can pose difficulties for manufacturers with limited technical expertise.
09-27
2014
Heat-recovery shell-and-tube heat exchanger
As society places increasingly urgent demands on energy conservation and low‑carbon development, heat‑exchanging equipment designed for waste‑heat and residual‑heat recovery is being adopted more and more widely. The refrigeration and air‑conditioning industries are key focus areas for energy efficiency; recovering the condensation heat from refrigeration and air‑conditioning units to produce domestic hot water or process hot water has become a widely used energy‑saving approach. Large refrigeration and air‑conditioning chillers typically employ shell-and-tube heat exchangers as their condensers. When implementing heat recovery from condensation in such systems, the condenser must be redesigned and modified. Generally, there are two approaches to heat recovery: partial heat recovery and full heat recovery. Partial heat recovery involves recovering only a portion of the condensation heat…
11-14
2015
Working principles and structures of dry-type, flooded-type, and falling-film evaporators
1. Working Principles and Structures of Dry-Type, Flooded-Type, and Falling-Film Evaporators: 1.1 Dry-Type Evaporator In a dry-type evaporator, the refrigerant flows inside the heat exchange tubes, while chilled water circulates outside the high-efficiency tubes. This type of heat exchanger has relatively lower heat transfer efficiency—its heat transfer coefficient is only about twice that of a smooth-tube heat exchanger. However, it offers the advantages of easy oil return and simpler control, and its refrigerant charge is roughly one‑half to one‑third of that required for a flooded‑type unit. 1.2 Flooded-Type Evaporator The flooded-type evaporator operates in the opposite manner to the dry-type evaporator: chilled water flows inside the heat exchange tubes, while the refrigerant completely…
09-25
2018
Method for Calculating the Heat Transfer Area of a Condenser
1. Calculation method for the heat transfer area of an air-cooled condenser: Refrigeration capacity + compressor motor power / 200–250 = condenser heat transfer area. For example: (3SS1-1500 compressor), CT = 40°C, CE = −25°C; compressor refrigeration capacity = 12,527 W; compressor motor power = 11,250 W; total cooling load = 23,777 W; thus, condenser heat transfer area = 23,777 / 230 = 103 m². 2. The ratio of water-cooled condenser heat transfer area to air-cooled condenser heat transfer area is approximately 1:18 (103/18) = 6 m². The evaporator area is determined based on the compressor’s refrigeration capacity, using a table that accounts for evaporation temperature (in °C) and the correction factor for relative humidity (Δt).
09-25
2018
Refrigeration Encyclopedia — Why Isn’t the Cold Storage Room Cooling, and How Can It Be Fixed?
1. When the evaporator surface in a cold storage room develops excessively thick frost or accumulates excessive dust, heat transfer efficiency declines, resulting in slow temperature reduction. A major cause is the low heat-transfer performance of the evaporator, primarily due to overly thick frost layers or excessive dust buildup on its surface. Since the evaporator’s surface temperature is usually below 0°C and the relative humidity inside the storage room is relatively high, moisture in the air readily condenses into frost and even ice on the evaporator surface, thereby impairing its heat-transfer capability. To prevent excessive frost accumulation, the evaporator surface should be defrosted regularly. Two relatively simple defrosting methods are introduced: ① Shutdown defrosting—this involves stopping the compressor and opening the storage room…