News Center
News Center
Image Name

NEWS

News Center

10-31

2018

These issues must be considered when replacing R22 with R404A refrigerant.

In China, R22 remains the most widely used refrigerant in the refrigeration industry. However, due to its ozone-depleting potential and high global warming impact, China has committed, in accordance with relevant international agreements, to phase out its use by 2030. Consequently, an increasing number of refrigeration and cold‑storage systems are transitioning to R404A as a replacement for R22. Although R404A offers similar cooling performance to R22, there are still several key differences in practical applications that warrant careful attention. When substituting R404A for R22, the following considerations should be taken into account: 1. The primary challenge in replacing R22 with R404A is the lubricant issue; it is essential to use compatible lubricants accordingly.


10-31

2018

Common Principles and Structures of Condensers

The condenser is one of the key components in a refrigeration system. It transfers the heat from the superheated refrigerant vapor to the surrounding air or water via its heat‑releasing surface, thereby cooling itself into saturated vapor and further condensing into a high‑pressure liquid, which then circulates within the system. The following section describes the operating principles and construction of common types of condensers. 1. Horizontal shell-and-tube condenser: Refrigerant vapor condenses on the outer surfaces of the tubes, while cooling water flows inside the tubes under the action of a pump. The refrigerant vapor enters through the upper inlet pipe and, after condensing into a liquid, exits via the lower outlet pipe at the bottom of the shell and flows into the receiver. The ends of the condenser shell are sealed with end caps, and these caps incorporate water‑distribution baffles.


12-17

2018

How do you adjust a thermostatic expansion valve? How should ice blockages or dirt blockages be handled?

The expansion valve is one of the four major components of a refrigeration system. It is a critical device for regulating and controlling the flow and pressure of the refrigerant as it enters the evaporator, and it also serves as the boundary between the high-pressure and low-pressure sides. Its adjustment not only determines whether the entire refrigeration system can operate properly but also serves as an important indicator of the operator’s skill level. Adjusting the expansion valve must be carried out carefully and patiently. The pressure change resulting from the adjustment becomes apparent on the pressure gauge only after the refrigerant has undergone heat exchange and vaporization in the evaporator, with the vapor then flowing through the piping into the compressor’s suction chamber—a process that takes time. Each time the expansion valve is adjusted, it typically requires 15 to 30 minutes for the changes to stabilize.


05-04

2019

2019 China Refrigeration Exhibition | A Comprehensive Review of Lengde’s Highlights

Collaborative Innovation, Shared Development On April 11, the 2019 China Refrigeration Exhibition officially opened at the Shanghai New International Expo Center. As one of the largest specialized trade shows in the global HVAC and refrigeration industry, it draws thousands of exhibitors from around the world each year and serves as a key platform for companies to showcase their latest products and technologies. At this year’s event, Nanjing Lengde was no exception, proudly presenting its core strengths. Founded in 1987, the China Refrigeration Exhibition has, through more than three decades of continuous growth, become one of the largest professional trade shows in the global HVAC and refrigeration sector, accredited by the Global Association of the Exhibition Industry (UFI) and the American…


07-19

2019

Warm congratulations to Nanjing Lengde on being recognized as the “2019 Nanjing Municipal Engineering Technology Research Center.”

To further implement the innovation-driven “121” strategy and promote high-quality development, in accordance with the Measures for the Administration of Nanjing Municipal Engineering Technology Research Centers (Ning Ke Gui [2015] No. 1), and following procedures including recommendations from district-level competent authorities and expert review, the “Nanjing Municipal Engineering Technology Research Center for Microwave Anechoic Chamber Systems,” established by Nanjing Luopu Technology Co., Ltd., along with 125 other engineering technology research centers, has been found to meet the criteria for project approval and has been designated as a municipal-level engineering technology research center.


12-01

2019

Working principle of a falling-film evaporator

The main body of a falling-film evaporator consists of numerous components, such as a thermal compression pump, a separator, insulated piping, a water pump, and an instrument cabinet. Each of these pieces of equipment has its own distinct characteristics and applications; among them, any component that comes into direct contact with the process material…


01-08

2020

The company organizes employee health check-ups to safeguard employees’ well-being.

As the company’s employee benefits system continues to improve, and in order to enhance employees’ occupational health and boost their work enthusiasm, the annual company-wide health checkup kicked off once again on January 5, 2020.


02-21

2020

“Epidemic” – A Duty We Cannot Shirk

“Epidemic” – A Duty We Cannot Shirk


< 1...789...11 >
< 1...789...11 >