Currently, screw-type water-cooled chillers are widely used in the large‑scale central air-conditioning market. As energy‑efficiency requirements continue to rise, these units are increasingly equipped with flooded evaporators—heat exchangers that offer a higher heat transfer coefficient. Because flooded evaporators rely on boiling heat transfer outside the tubes, they deliver superior thermal performance, enabling higher evaporation temperatures and smaller temperature differences across the heat exchanger, thereby improving the chiller’s energy efficiency ratio. However, flooded‑type systems also present certain technical challenges, resulting in higher failure rates and greater costs compared with dry‑type units. Moreover, oil return in flooded systems is more difficult than in dry‑type systems, and their control strategies are more complex, which can pose difficulties for manufacturers with limited technical expertise.
09-27
2014
Heat-recovery shell-and-tube heat exchanger
As society places increasingly urgent demands on energy conservation and low‑carbon development, heat‑exchanging equipment designed for waste‑heat and residual‑heat recovery is being adopted more and more widely. The refrigeration and air‑conditioning industries are key focus areas for energy efficiency; recovering the condensation heat from refrigeration and air‑conditioning units to produce domestic hot water or process hot water has become a widely used energy‑saving approach. Large refrigeration and air‑conditioning chillers typically employ shell-and-tube heat exchangers as their condensers. When implementing heat recovery from condensation in such systems, the condenser must be redesigned and modified. Generally, there are two approaches to heat recovery: partial heat recovery and full heat recovery. Partial heat recovery involves recovering only a portion of the condensation heat…
11-14
2015
Working principles and structures of dry-type, flooded-type, and falling-film evaporators
1. Working Principles and Structures of Dry-Type, Flooded-Type, and Falling-Film Evaporators: 1.1 Dry-Type Evaporator In a dry-type evaporator, the refrigerant flows inside the heat exchange tubes, while chilled water circulates outside the high-efficiency tubes. This type of heat exchanger has relatively lower heat transfer efficiency—its heat transfer coefficient is only about twice that of a smooth-tube heat exchanger. However, it offers the advantages of easy oil return and simpler control, and its refrigerant charge is roughly one‑half to one‑third of that required for a flooded‑type unit. 1.2 Flooded-Type Evaporator The flooded-type evaporator operates in the opposite manner to the dry-type evaporator: chilled water flows inside the heat exchange tubes, while the refrigerant completely…
09-25
2018
Method for Calculating the Heat Transfer Area of a Condenser
1. Calculation method for the heat transfer area of an air-cooled condenser: Refrigeration capacity + compressor motor power / 200–250 = condenser heat transfer area. For example: (3SS1-1500 compressor), CT = 40°C, CE = −25°C; compressor refrigeration capacity = 12,527 W; compressor motor power = 11,250 W; total cooling load = 23,777 W; thus, condenser heat transfer area = 23,777 / 230 = 103 m². 2. The ratio of water-cooled condenser heat transfer area to air-cooled condenser heat transfer area is approximately 1:18 (103/18) = 6 m². The evaporator area is determined based on the compressor’s refrigeration capacity, using a table that accounts for evaporation temperature (in °C) and the correction factor for relative humidity (Δt).
09-25
2018
Refrigeration Encyclopedia — Why Isn’t the Cold Storage Room Cooling, and How Can It Be Fixed?
1. When the evaporator surface in a cold storage room develops excessively thick frost or accumulates excessive dust, heat transfer efficiency declines, resulting in slow temperature reduction. A major cause is the low heat-transfer performance of the evaporator, primarily due to overly thick frost layers or excessive dust buildup on its surface. Since the evaporator’s surface temperature is usually below 0°C and the relative humidity inside the storage room is relatively high, moisture in the air readily condenses into frost and even ice on the evaporator surface, thereby impairing its heat-transfer capability. To prevent excessive frost accumulation, the evaporator surface should be defrosted regularly. Two relatively simple defrosting methods are introduced: ① Shutdown defrosting—this involves stopping the compressor and opening the storage room…
10-31
2018
These issues must be considered when replacing R22 with R404A refrigerant.
In China, R22 remains the most widely used refrigerant in the refrigeration industry. However, due to its ozone-depleting potential and high global warming impact, China has committed, in accordance with relevant international agreements, to phase out its use by 2030. Consequently, an increasing number of refrigeration and cold‑storage systems are transitioning to R404A as a replacement for R22. Although R404A offers similar cooling performance to R22, there are still several key differences in practical applications that warrant careful attention. When substituting R404A for R22, the following considerations should be taken into account: 1. The primary challenge in replacing R22 with R404A is the lubricant issue; it is essential to use compatible lubricants accordingly.
10-31
2018
Common Principles and Structures of Condensers
The condenser is one of the key components in a refrigeration system. It transfers the heat from the superheated refrigerant vapor to the surrounding air or water via its heat‑releasing surface, thereby cooling itself into saturated vapor and further condensing into a high‑pressure liquid, which then circulates within the system. The following section describes the operating principles and construction of common types of condensers. 1. Horizontal shell-and-tube condenser: Refrigerant vapor condenses on the outer surfaces of the tubes, while cooling water flows inside the tubes under the action of a pump. The refrigerant vapor enters through the upper inlet pipe and, after condensing into a liquid, exits via the lower outlet pipe at the bottom of the shell and flows into the receiver. The ends of the condenser shell are sealed with end caps, and these caps incorporate water‑distribution baffles.
12-17
2018
The expansion valve is one of the four major components of a refrigeration system. It is a critical device for regulating and controlling the flow and pressure of the refrigerant as it enters the evaporator, and it also serves as the boundary between the high-pressure and low-pressure sides. Its adjustment not only determines whether the entire refrigeration system can operate properly but also serves as an important indicator of the operator’s skill level. Adjusting the expansion valve must be carried out carefully and patiently. The pressure change resulting from the adjustment becomes apparent on the pressure gauge only after the refrigerant has undergone heat exchange and vaporization in the evaporator, with the vapor then flowing through the piping into the compressor’s suction chamber—a process that takes time. Each time the expansion valve is adjusted, it typically requires 15 to 30 minutes for the changes to stabilize.
12-01
2019
Working principle of a falling-film evaporator
The main body of a falling-film evaporator consists of numerous components, such as a thermal compression pump, a separator, insulated piping, a water pump, and an instrument cabinet. Each of these pieces of equipment has its own distinct characteristics and applications; among them, any component that comes into direct contact with the process material…