Design of a Water-Cooled Screw Chiller System for Air Conditioning

Common water-cooled screw chillers are primarily classified into three types based on evaporator design: dry‑type units, flooded‑type units, and falling‑film units. The core component of a water‑cooled screw chiller is the screw compressor; the market is dominated by twin‑screw compressors, with a few manufacturers opting for single‑screw models. Most compressors are semi‑hermetic, though some manufacturers also offer open‑type or fully hermetic designs. With the exception of major U.S. and Japanese brands, domestic manufacturers generally source their compressors from external suppliers. The system designs of dry‑type water‑cooled screw chillers across different manufacturers are largely similar, differing mainly in heat exchanger and throttling‑device configurations. On the market, leading manufacturers employ broadly comparable condenser designs (condensing…


09-27

2014

Flooded evaporator

Currently, screw-type water-cooled chillers are widely used in the large‑scale central air-conditioning market. As energy‑efficiency requirements continue to rise, these units are increasingly equipped with flooded evaporators—heat exchangers that offer a higher heat transfer coefficient. Because flooded evaporators rely on boiling heat transfer outside the tubes, they deliver superior thermal performance, enabling higher evaporation temperatures and smaller temperature differences across the heat exchanger, thereby improving the chiller’s energy efficiency ratio. However, flooded‑type systems also present certain technical challenges, resulting in higher failure rates and greater costs compared with dry‑type units. Moreover, oil return in flooded systems is more difficult than in dry‑type systems, and their control strategies are more complex, which can pose difficulties for manufacturers with limited technical expertise.


09-27

2014

Heat-recovery shell-and-tube heat exchanger

As society places increasingly urgent demands on energy conservation and low‑carbon development, heat‑exchanging equipment designed for waste‑heat and residual‑heat recovery is being adopted more and more widely. The refrigeration and air‑conditioning industries are key focus areas for energy efficiency; recovering the condensation heat from refrigeration and air‑conditioning units to produce domestic hot water or process hot water has become a widely used energy‑saving approach. Large refrigeration and air‑conditioning chillers typically employ shell-and-tube heat exchangers as their condensers. When implementing heat recovery from condensation in such systems, the condenser must be redesigned and modified. Generally, there are two approaches to heat recovery: partial heat recovery and full heat recovery. Partial heat recovery involves recovering only a portion of the condensation heat…


11-14

2015

Working principles and structures of dry-type, flooded-type, and falling-film evaporators

1. Working Principles and Structures of Dry-Type, Flooded-Type, and Falling-Film Evaporators: 1.1 Dry-Type Evaporator In a dry-type evaporator, the refrigerant flows inside the heat exchange tubes, while chilled water circulates outside the high-efficiency tubes. This type of heat exchanger has relatively lower heat transfer efficiency—its heat transfer coefficient is only about twice that of a smooth-tube heat exchanger. However, it offers the advantages of easy oil return and simpler control, and its refrigerant charge is roughly one‑half to one‑third of that required for a flooded‑type unit. 1.2 Flooded-Type Evaporator The flooded-type evaporator operates in the opposite manner to the dry-type evaporator: chilled water flows inside the heat exchange tubes, while the refrigerant completely…


09-25

2018

Method for Calculating the Heat Transfer Area of a Condenser

1. Calculation method for the heat transfer area of an air-cooled condenser: Refrigeration capacity + compressor motor power / 200–250 = condenser heat transfer area. For example: (3SS1-1500 compressor), CT = 40°C, CE = −25°C; compressor refrigeration capacity = 12,527 W; compressor motor power = 11,250 W; total cooling load = 23,777 W; thus, condenser heat transfer area = 23,777 / 230 = 103 m². 2. The ratio of water-cooled condenser heat transfer area to air-cooled condenser heat transfer area is approximately 1:18 (103/18) = 6 m². The evaporator area is determined based on the compressor’s refrigeration capacity, using a table that accounts for evaporation temperature (in °C) and the correction factor for relative humidity (Δt).


09-25

2018

Refrigeration Encyclopedia — Why Isn’t the Cold Storage Room Cooling, and How Can It Be Fixed?

1. When the evaporator surface in a cold storage room develops excessively thick frost or accumulates excessive dust, heat transfer efficiency declines, resulting in slow temperature reduction. A major cause is the low heat-transfer performance of the evaporator, primarily due to overly thick frost layers or excessive dust buildup on its surface. Since the evaporator’s surface temperature is usually below 0°C and the relative humidity inside the storage room is relatively high, moisture in the air readily condenses into frost and even ice on the evaporator surface, thereby impairing its heat-transfer capability. To prevent excessive frost accumulation, the evaporator surface should be defrosted regularly. Two relatively simple defrosting methods are introduced: ① Shutdown defrosting—this involves stopping the compressor and opening the storage room…